New developments in short-range distance sensing technology.
Biology ultimately comes down to chemistry and structure, usually of molecules that are rather small. Seeing them has been a big challenge through the decades, and successful visualization has led to significant advances, such as the original structure of DNA, to take one example. The premier method has been X-ray crystallography, more recently superceded by electron cryomicroscopy. Both of these methods use powerful, ultra-short-wave radiation and mathematical methods to reconstruct complete structures of static molecules. In each case, the subjects have to keep very still in order to have their picture taken. While it is often possible to lock proteins of interest in more than one static conformation for these analyses, such as bound to a substrate, and then without, dynamics have to be inferred or guessed from the further application of math in the form of molecular dynamics.
NMR has been a supplementary method for small molecules, which allows some dynamic analysis, but there have also been a large number of more ad-hoc methods to gain structural insight when full structures or dynamic behavior is inaccessible, such as cross-linking, immunolabeling, complex purification, and systematic genetic mutation. One of the most magical of these non-comprehensive structure methods is Förster resonance energy transfer (FRET) between pairs of fluorescent elements. Such elements can communicate directly, via their light emissions, how close they are, and thus can give rather direct information on specific structural aspects of a molecular system in an immediate, dynamic, and convenient way.
If two fluorescent molecules are close to each other, and the radiation absorbance spectrum of the acceptor is at a slightly lower energy than the emission spectrum of the donor, then instead of fluorescing away a photon, there is a good chance that the donor will transfer its electronic excitation directly, via resonance through the mediating electric field structures, to the acceptor molecule, which may (or may not) then emit the energy in its own emission wavelenght, somewhat longer than that of the donor. Obviously, this is very distance-dependant, and the distance at which the chances of resonant transfer are 50% is termed R0. This distance is surprisingly far for many pairs of robustly fluorescing molecules- on the order of 60 or 70 Ångstroms (Å), or tenths of a nanometer.
This is obviously great for some things. Photosynthesis, for instance, relies on the rapid and quantitative transfer of this kind of resonance energy from the various light-gathering antenna complexes to the photocenter where chemical reactions can take place. A recent direction in this structure field, (paper 1, 2), however, is to recognize that for detailed structure work, these distances are too far, and a finer ruler is needed. Additionally, two other issues have come up. Typical fluorophores are very direction-dependent, with large organic rings that gain excitation and generate emission preferentially in certain directions. Secondly, they are typically mounted on long tethers. Both of these properties reduce the ability to infer distances in any confident way from FRET measurements.
So the recent improvements amount to using worse fluorophores, specifically metals like copper, cobalt, and nickel, which reduce the working distance of FRET to 10 - 20 Å, and have a much more isotropic excitation profile, which is to say that they are direction-neutral, due to their simple, single-atom nature. This allows finer working distances and more accurate inferences about distance, when the intended span can be engineered to under 20 Å. For comparison, a lipid bilayer membrane is 100 Å across, and a protein alpha helix is 5.4 Å per turn, making 20 Å about 3.7 turns. One drawback to the new method is that the metal acceptors do not in turn fluoresce at a longer wavelength- they only quench the donor's fluorescence. That makes the structure professionals happy, reducing stray signals, but at the cost of some extra certainty of what is going on, not to mention some of the magic of this method.
The model system most researchers use to guage new methods is maltose binding protein, (MBP), which closes like a clam when binding the sugar maltose (pink). The amino acid positions noted 237 and 295 are about 13 Å apart in the bound state, as shown, and separate to 21 Å in the naked state. There are additional innovations in how fluorescence probes are engineered into the protein and managed, that won't be discussed. The new paper shows that, when everything is placed properly, fluorescence from the donor is cut in half as maltose is added, and if they plug all this into appropriate mathematical models of the system, they get an implied distance estimate within a couple of Ångstroms of the true values- a significant advance in accuracy for this kind of method.
While the major (comprehensive) structural methods are gaining convenience and accuracy, these extra methods of structure estimation can be lifesavers in special situations where some dynamic aspect of a system is in question. For example, another paper from this group looked at a cyclic nucleotide-gated cation channel that functions in smell, vision, and the central nervous system, being directly activated by key second messengers like cAMP. They positioned one probe on the membrane surface and another in the protein domain nearby which is a key hinge conducting the cAMP/cGMP binding signal to the channel. They found a close correlation between activity of the channels and how close their probe, and thus the hinge region, is to the membrane, thus giving a little more structural insight into this protein family.